Description:
Oral liquid
compounding system includes sugar melting, initial compounding, cold storage,
filtration/centrifugation, fine compounding, heating/cooling, material transfer,
CIP/SIP and control system.
For
multi-tank compounding system, advanced adapter plate design process is
adopted. Tank cleaning can be completely independent of pipe, so as to avoid
leakage of materials, pollution and risk of false operation. In this way, less
dead ends will present in pipe system and cleaning will be easier.
Piping and
equipment meets requirements of GMP production, without blind pipe and dead
ends. Installation of equipment and accessories facilitates disassembly,
maintenance and repair.
Structure
design of steel platform is reasonable, so it will be easy for operating and
carrying out all kinds of cleaning work.
Control
system meets operation requirements of production process. Relevant parameters
of compounding system can be monitored and recorded in real time, to ensure
quality tracking and tracing.
After
detailed design and before construction, the whole system will be
three-dimensional designed according to layout of field equipment.
Ideal
provides a full set of validation services, including risk assessment (RA),
design qualification (DQ), installation qualification (IQ), operational
qualification (OQ), etc.